Imagem 1

 

ORIGINAL ARTICLE

 

ADHERENCE TO GOOD PRACTICES IN THE PREVENTION OF VENTILATOR-ASSOCIATED PNEUMONIA: A CROSS-SECTIONAL STUDY

 

Beatriz Cristina da Silva1, Lucas Rodrigo Garcia de Mello1, Danielle Mendonça Henrique1, Ayla Farias de Mesquita1, Raquel de Mendonça Nepomuceno1, Luana Ferreira de Almeida1, Caroline de Deus Lisboa1, Barbara Pompeu Christovam2

 

1 Universidade Estadual do Rio de Janeiro, RJ, Brazil

2 Universidade Federal Fluminense, RJ, Brazil

 

ABSTRACT

Objective: to evaluate best practices for preventing ventilator-associated pneumonia in patients on invasive mechanical ventilation admitted to intensive care. Method: this is a cross-sectional, prospective study with a quantitative approach, assessing professionals' adherence to three items that comprise the ventilator-associated pneumonia prevention bundle. Descriptive analysis was based on absolute and relative frequency distributions and calculation of descriptive statistics for quantitative variables. Results: the item with the highest adherence was maintaining the head of the bed elevated, with 68.85% compliance, followed by maintaining cuff pressure between 25 and 30 mmHg, with 55.74%. Oral hygiene had the lowest adherence, with 32.79%. Regarding the entire bundle, the compliance rate was 21.31%. Conclusion: the highest adherence rate was observed for elevating the head of the bed, followed by monitoring cuff pressure, while oral hygiene had the lowest adherence. Maintaining cuff pressure within recommended values ​​was associated with a reduced risk. Furthermore, full adherence to the bundle resulted in a significant reduction in the incidence of ventilator-associated pneumonia.

 

Descriptors: Ventilator-Associated Pneumonia; Intensive Care; Oral Hygiene; Patient Safety.

 

How to cite: Silva BC, Mello LRG, Henrique DM, Mesquita AF, Nepomuceno RM, Almeida LF, et al. Adherence to good practices in the prevention of ventilator-associated pneumonia: a cross-sectional study. Online Braz J Nurs. 2025;24:e20256876. https://doi.org/10.17665/1676-4285.20256876

 

INTRODUCTION

In the intensive care unit (ICU), one of the main therapeutic interventions is invasive mechanical ventilation, which can be implemented through an endotracheal tube (orotracheal or nasotracheal) or a tracheostomy. However, the use of these devices increases the risk of respiratory infections, with ventilator-associated pneumonia (VAP) being one of the most frequent complications(1).

This severe infection affects the lung parenchyma and compromises gas exchange essential for oxygenation, particularly in patients who remain intubated for more than 48 hours. The predisposition to VAP arises from the fact that the use of ventilatory prostheses in patients receiving invasive mechanical ventilation interferes with the body’s natural defense mechanisms, thereby increasing vulnerability to microbial invasion of the respiratory system. These microorganisms can pass through the space between the trachea and the tube, reaching the lower respiratory tract(2–3). VAP is among the most common healthcare-associated infections, with a national incidence of 12.51 cases per 1,000 days of mechanical ventilation and 11.09 cases in the state of Rio de Janeiro. It is also associated with prolonged hospitalization, increased healthcare costs, and, most critically, high mortality rates ranging from 24% to 76%, reflecting heterogeneity among patients and intensive care settings(1,4-5).

In response to this problem, the Brazilian Health Regulatory Agency (ANVISA), following the guidelines of the Institute for Healthcare Improvement (IHI)—an organization recognized worldwide for promoting excellence in healthcare—developed a set of strategies aimed at addressing modifiable risk factors to reduce the occurrence of VAP. Although these measures may seem simple, they have proven effective in decreasing the incidence of VAP when applied in a coordinated and integrated manner(4-7).

These strategies include elevating the head of the bed to an angle between 30° and 45°, performing daily assessments for sedation interruption, regular subglottic suctioning, and maintaining oral hygiene with a 0.12% chlorhexidine solution. In addition, other recommendations, which are not part of the IHI guidelines but are included in ANVISA’s protocols, involve monitoring cuff pressure, judicious use of neuromuscular blocking agents, and appropriate care of the ventilator circuit, among others(4-7).

However, although this set of measures has demonstrated its effectiveness in preventing VAP, a significant disparity is often observed between the recommended ideals and the actions actually implemented(6).

Although several studies address the prevention of VAP and the consequent reduction in its incidence, there is a scarcity of research examining this issue from the perspective of nursing care, especially in light of recently published guidelines, and exploring its association with clinical outcomes.

Based on this premise, the present study aims to evaluate best practices for preventing ventilator-associated pneumonia in patients on invasive mechanical ventilation admitted to intensive care.

 

METHOD

This is an observational, cross-sectional study with a quantitative approach, following the 22 steps of the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) recommendations. It assessed healthcare professionals' adherence to three items that comprise the VAP prevention package: elevated headboard, oral hygiene, and cuff pressure assessment(7).

The study was conducted in two intensive care units of a university hospital in Rio de Janeiro between March and July 2024. Neither unit had a pre-established care protocol for VAP prevention. The care provided to 65 patients was analyzed according to the inclusion and exclusion criteria of this study. The inclusion criteria were: Adult patients admitted to intensive care using invasive mechanical ventilation via orotracheal tube or tracheostomy for more than 48 hours. Pregnant patients and those undergoing neurosurgical procedures were excluded from the study, as the duration of invasive mechanical ventilation in this population is generally less than 48 hours.

To assess adherence, three components of the VAP prevention bundle were directly observed: oral hygiene, cuff pressurization, and headboard elevation. These items were selected because they are specific nursing interventions, unlike daily wake-up calls and thrombosis prophylaxis, which require a physician's prescription.

Regarding oral hygiene, the presence or absence of soiling was assessed. Cuff values ​​between 20 and 30 mmHg were considered, and the measurement was performed using the cuffometer available in both units. Regarding the headboard, the elevation was verified between 30 and 45 degrees, using the leveler located on the side of the bed, available in all beds. Data collection was performed by a single researcher between 10:00 a.m. and 12:00 p.m. on random days.

Data collection was performed using an electronic instrument integrated with the patient's electronic medical record, called the Epimed Monitor UTI System. This instrument includes patient characteristics, demographic data (age, gender, and race), and clinical data (primary and secondary diagnoses, comorbidities, functional capacity, severity according to the Simplified Acute Physiology Score 3 (SAPS 3), and ventilatory parameters. The data obtained were extracted into an Excel spreadsheet format from the Epimed Monitor UTI System and statistically analyzed.

The descriptive analysis was based on absolute and relative frequency distributions and calculation of descriptive statistics for quantitative variables (minimum, maximum, mean, median, standard deviation, and coefficient of variation). Initially, the sample normality test was used. Subsequently, the chi-square test and Fisher's exact test were used to determine the association between oral hygiene compliance and the following outcomes: duration of MV and occurrence of VAP, with p < 0.05 as the standard of significance.

 

Ethical issues of research

The research was approved by the Research Ethics Committee of the State University of Rio de Janeiro under Opinion No. 5,997,457 and Certificate of Presentation of Ethical Appreciation (CAAE): 26827219.8.0000.5259, in accordance with Resolution No. 466/12 of the National Health Council. The research is linked to a broad-scope project entitled "Healthcare-Related Infection Indicators: Tools for Nursing Care." The Informed Consent Form (ICF) was applied to the patients' guardians for direct observation and consultation of patient records. Furthermore, all data were anonymized and coded in accordance with the Law for General Data Protection (LGPD).

 

RESULTS

Sixty-one patients participated in the study. Among these, there was a predominance of females (55.74%) and a diagnosis of infection/sepsis (57.38%). The mean age of the participants was 60.37 (±11.47) years. Of the total, 72.73% of the participants died, as shown in Table 1.

 

Table 1 – Sociodemographic and clinical characterization of participants (n=61). Rio de Janeiro, RJ, Brazil, 2024

Variables

N

%

Gender

 

 

Female

34

55.74

Male

27

44.26

Readmission

 

 

Yes

7

11.48

No

54

88.52

Readmission >24 hours

 

 

No

61

100.0

Outcome in the unit

 

 

Discharge

15

28.3

Death

38

71.7

Hospital outcome

 

 

Discharge

15

27.27

Death

40

72.73

Patient orgin

 

 

Ward/Room

23

37.7

Surgical center/hemodynamics

19

31.15

Transfer from another hospital/institution

15

24.59

Semi-intensive Unit

1

1.64

Another ICU/ICU in your hospital

3

4.92

Diagnostic category

 

 

Infection/sepsis

35

57.38

Tumors and oncological complications

10

16.39

Neurological / psychiatric

6

9.84

Liver, Bile Ducts, Spleen and Pancreas

3

4.92

Respiratory (except sepsis/infection)

3

4.92

Abdominal/retroperitoneal surgeries

1

1.64

Endocrine/metabolic

1

1.64

Cardiopulmonary arrest

1

1.64

Renal

1

1.64

Variables

Mean (±SD)

Median (IIQ)

Minimum/maximum

Age

60.37 years (11.47)

62 years old (38)

36/ 80

Length of stay in the ICU

25.16 days (14.43)

22 days (52)

5/ 65

Length of stay in hospital

37.07 days (28.25)

30 days (78)

8/ 110

Duration time in VM

14.54 days (7.27)

14 days (20)

4/ 36

N=53. N = 50.

 

Table 2 presents the characterization of the items in the VAP prevention bundle. The most frequently completed item was elevating the head of the bed (68.85%), followed by maintaining cuff pressure within the target range (55.74%). The prevalence of VAP was 50.82%.

 

Table 2 – Characterization of ventilator-associated pneumonia prevention bundle items and the occurrence of VAP. (n=61). Rio de Janeiro, RJ, Brazil, 2024

Variables

N

%

Raised headboard

 

 

Yes

42

68.85

No

19

31.15

Cuff pressure within the target

 

 

Yes

34

55.74

No

27

44.26

Oral hygiene protocol with chlorhexidine

 

Yes

20

32.79

No

41

67.21

Full compliance with the MVAP prevention bundle

 

Yes

13

21.31

No

48

78.69

VAP

 

 

Yes

31

50.82

No

30

49.18

 

Table 3 presents the associations between sociodemographic and clinical characteristics and the occurrence of VAP. Patient origin, age group, length of ICU stay, and cuff pressure within the target range were associated with the occurrence of VAP. Being 60 years of age or older increases the chance of VAP by 3.91 times (95% CI 1.29; 11.84). Patients whose cuff pressure is within the target range have an 84% lower chance of VAP (95% CI 0.05; 0.51). Full compliance with the three-item bundle (headboard, cuff, and hygiene) showed a 79% reduction in the chance of VAP (95% CI 95% to 23%).

 

Table 3 – Association between sociodemographic and clinical characteristics and occurrence of VAP. (n=61). Rio de Janeiro, RJ, Brazil, 2024

 

Variables

Occurrence of VAP

 

OR

 

CI95%

p-value

Yes

No

N

%

N

%

Gender

 

 

 

 

 

 

0.091

Female

14

41.18

20

58.82

0.41

0.14; 1.16

Male

17

62.96

10

37.04

1

-

Age range

 

 

 

 

 

 

0.013

36 to 59 years old

7

30.43

16

69.57

1

-

60 years old or more

24

63.16

14

36.84

3.91

1.29; 11.84

Patient origin

 

 

 

 

 

0.021

Ward/Room

15

65.22

8

34.78

1

-

Others

9

47.37

10

52.63

0.48

0.13; 1.66

Transfer from another hospital/ Institution

3

20.0

12

80.0

0.13

0.02; 0.61

Semi-intensive Unit

1

100.0

0

0

-

-

Another ICU/ICU in your hospital

3

100.0

0

0

-

-

Diagnostic category

 

 

 

 

 

0.152

Infection/sepsis

15

42.86

20

57.14

0.46

0.16; 1.32

Others

16

61.54

10

38.46

1

-

Length of stay in the ICU

 

 

 

 

0.008

One to 10 days

6

85.71

1

14.29

1

-

11 to 20 days

14

66.67

7

33.33

0.33

0.03; 3.33

21 days or more

11

33.33

22

66.67

0.08

0.01; 0.78

Duration time in VM

 

 

 

 

0.454

One to 10 days

13

61.9

8

38.1

1

-

11 to 20 days

10

45.45

12

54.55

0.51

0.15; 1.73

21 days or more

8

44.44

10

55.56

0.49

0.13; 1.77

Raised headboard

 

 

 

 

0.064

Yes

18

42.86

24

57.14

0.34

0.11; 1.08

No

13

68.42

6

31.58

1

-

Cuff pressure within the target

 

 

 

 

0.001

Yes

11

32.35

23

67.65

0.16

0.05; 0.51

No

20

74.07

7

25.93

1

-

Oral hygiene protocol with chlorhexidine

 

 

0.525

Yes

9

45.0

11

55.0

0.70

0.24; 2.06

No

22

53.66

19

46.34

1

-

Full compliance with the bundle

 

 

 

0.024

Yes

3

23.08

10

76.92

0.21

0.05; 0.87

No

28

58.33

20

41.67

1

-

Chi-square test. ‡ Fisher's exact test. 95% CI = 95% Confidence Interval.

 

Table 4 shows the associations between sociodemographic and clinical characteristics and clinical outcome (discharge or death) of participants in the unit. Gender, age range, diagnostic category, length of stay in the ICU, head-of-bed elevation, cuff pressure within the target range, and oral hygiene protocol with chlorhexidine were associated with the clinical outcome of participants. The variables associated with the outcome were: age with the highest mortality rate and full compliance with the bundle with the best clinical outcome.

 

Table 4 – Association between sociodemographic and clinical characteristics and clinical outcome of participants in the unit (discharge or death) (n=61). Rio de Janeiro, RJ, Brazil, 2024

Variables

Clinic outcome

OR

CI95%

p-value

Discharge

Death

N

%

N

%

Gender

 

 

 

 

 

 

0,020

Female

12

41.38

17

58.62

0.20

0.04; 0.83

Male

3

12.5

21

87.5

1

-

Age range

 

 

 

 

 

 

<0.001

36 to 59 years

14

73.68

5

26.32

1

-

60 years old or more

1

2.94

33

97.06

92.4

9.87; 864.64

Patient origin

 

 

 

 

 

0.260

Ward/Room

5

29.41

12

70.59

1

-

Surgical center

2

10.53

17

89.47

3.54

0.59; 21.39

Transfer from another hospital/ Institution

7

53.85

6

46.15

0.35

0.07; 1.61

Semi-intensive Unit

1

100.0

0

0

-

-

Another ICU/ICU in your hospital

0

0

3

100.0

-

-

Diagnostic category

 

 

 

 

 

0.023

Infection/Sepsis

13

40.63

19

59.37

0.15

0.03; 0.77

Other

0

0

9

100.0

1

-

ICU Length of Stay

 

 

 

 

0.002

One to 10 Days

0

0

7

100.0

-

-

11 to 20 Days

2

10.0

18

90.0

1

-

21 Days or More

13

50.0

13

50.0

0.05

0.01; 0.47

MV Length of Stay

 

 

 

 

0.104

One to 10 Days

3

15.0

17

85.0

1

-

11 to 20 Days

6

28.57

15

71.43

0.44

0.09; 2.07

21 Days or More

6

50.0

6

50.0

0.17

0.03; 0.93

Raised headboard

 

 

 

 

0.019

Yes

14

37.84

23

62.16

0.10

0.01; 0.92

No

1

6.25

15

93.75

1

-

Cuff pressure within the target

 

 

 

 

0.003

Yes

13

44.83

16

55.17

0.11

0.02; 0.56

No

2

8.33

22

91.67

1

-

Oral hygiene protocol with chlorhexidine

 

 

0.001

Yes

10

58.82

7

41.18

0.11

0.02; 0.43

No

5

13.89

31

86.11

1

-

Full compliance with the bundle

 

 

<0.001

Yes

8

72.73

3

27.27

0.075

0.01; 0.35

No

7

16.67

35

83.33

1

-

Chi-square test. ‡ Fisher's exact test. 95% CI = 95% Confidence Interval.

 

DISCUSSION

The most widely adopted practice in this study was head-of-bed elevation, with a 68.85% adherence rate. This rate is higher than that observed in a study conducted in Rio Grande do Sul, which recorded an adherence rate of 34.5%. However, it is still considered low when compared to studies conducted in other regions of the Southeast in 2019, where adherence rates were considerably higher, reaching 88.7% and 90.05%, respectively(9-11).

Head-of-bed elevation is an easy-to-apply, low-cost measure that helps improve respiratory patterns by increasing tidal volume. It also helps reduce the risk of bronchoaspiration of contents from the upper airways and gastrointestinal tract, thus becoming an important ally in preventing VAP(11-12).

Despite being the item with the highest adherence rate in the study, due to its low cost and ease of implementation, adherence rates were expected to be higher than those observed. This leads us to question the reasons for this rate. One possibility is that the headboard is manipulated by different professionals during their activities, which may have contributed to the variation in adherence. Furthermore, there may be a tendency to elevate the headboard and believe the level is adequate, without checking the bedside leveler, which was available at all beds.

In the present study, 62.96% of patients who developed VAP were male. Of the 61 patients analyzed, 50.82% acquired VAP during their hospitalization, and the majority were 60 years of age or older. These data are in line with the literature, which indicates that male gender and age over 60, among other factors, constitute risk factors for the development of VAP(3).

The rate of adequate cuff pressurization was 55.74%, the second highest among the patients analyzed. This result, exceeding 50%, is attributed to the ongoing training offered to nursing residents, the practical application of this knowledge in in-person training sessions with the entire team, and the theoretical-practical coordination established between medical, nursing, and physical therapy residents. In a study conducted in Santa Catarina, this rate was even higher, reaching 61.8%(12-13). In a study conducted in Rio de Janeiro, the researcher identified variations in cuff pressurization after nursing care, such as bed baths, tracheal suctioning, and position changes. These variations may be some of the reasons for the lower-than-expected observed numbers(14).

When properly pressurized, the cuff plays a crucial role in ensuring airway sealing. This prevents the migration of contaminated secretions from the upper to the lower airways, acting as an effective barrier between the space between the tube and the tracheal wall. It is worth noting that the Brazilian consensus on mechanical ventilation proposed by AMIB recommends that nurses monitor cuff pressure, ensuring safe levels before and after oral hygiene(15).

Aqueous chlorhexidine 0.12% is the recommended antiseptic solution for patients on mechanical ventilation, as it helps reduce bacterial plaque and the occurrence of VAP. Furthermore, some studies suggest that its effect is enhanced when preceded by mechanical biofilm removal. However, there is moderate evidence suggesting that daily toothbrushing without chlorhexidine may be effective. Other studies indicate that chlorhexidine may not have a significant impact on reducing the incidence of VAP, duration of mechanical ventilation, or hospital stay, and its exclusion did not result in significant differences in these metrics or in mortality rates(15-16).

Regarding oral hygiene, it was the item with the lowest adherence rate in our study, with compliance of only 32.79% of the patients evaluated, lower than a study conducted in the Northeast, which recorded a compliance rate of 48.86%, and a study in São Paulo, which recorded a compliance rate of 50%(17-18). It is important to highlight that the evaluation models used in previously published studies differ from the one adopted in this study, as the former used chlorhexidine as a parameter, while the latter considered the presence of tongue coating. It is believed that some patients' difficulty relaxing their oral cavity muscles may have limited the effectiveness of hygiene.

It is also noteworthy that the unit did not have a dental professional to contribute to the effectiveness of care, and that, according to the current care plan, the oral hygiene routine was performed twice a day. Based on the findings of this study, the frequency was increased to four times a day. It is worth noting that the Brazilian Consensus on Mechanical Ventilation does not establish the frequency of oral hygiene, but recommends that it include mechanical removal of biofilm through brushing or manual cleaning(15).

However, the importance of training that demonstrates the correct way to perform this practice is also highlighted, which should be further emphasized. It is essential not only to use antiseptic, but also to make an effective effort to remove dirt and plaque, as this is what will truly yield results. In a survey conducted in a hospital in Brasília, 19.4% of nurses reported facing difficulties in implementing this practice, making it the second most difficult item reported(2).

Finally, in this study, only 21.31% of patients had the bundle fully implemented, a result significantly lower than the average observed in other studies, such as the one in Porto Alegre, which achieved a rate of 92.7%. However, this figure is quite similar to that of the study conducted in São Paulo, which recorded a 21.7% compliance rate(10-21).

In this context, the most recent systematic review with meta-analysis, published in 2023, included 36 studies involving 116,873 participants focusing on adherence to the VAP prevention bundle. The results showed wide variation in self-reported adherence (38.5% and 100%). Despite this heterogeneity, a significant reduction in the occurrence of VAP was observed among patients in whom the bundle was implemented, compared to those who did not receive the care bundle (OR = 0.42; 95% CI: 0.33–0.54)(16).

That said, it's essential to understand that no single measure can prevent microorganisms from reaching the lungs. This justifies the need for comprehensive compliance with the bundle, as the study in question demonstrated a 79% reduction in the risk of VAP when all interventions were implemented together.

As a limitation, it's worth noting that the study was conducted in only two intensive care units, despite the healthcare institution having five units. Furthermore, no stratification was performed into subgroups of patients undergoing mechanical ventilation via tracheostomy and orotracheal or nasotracheal tubes, which could have provided more detailed and comparative analyses across patients.

 

CONCLUSION

Analysis of the bundle components revealed that the highest adherence rate was observed for head-of-bed elevation, followed by cuff pressure monitoring, while oral hygiene showed the lowest adherence. Being 60 years old or older increased the likelihood of VAP, while maintaining cuff pressure within recommended values ​​was associated with a reduced risk. Furthermore, full adherence to the bundle resulted in a significant decrease in the incidence of VAP. These findings highlight the importance of periodic training on the care of patients on mechanical ventilation and continuous nursing supervision in care practice, both considered essential elements for improving the quality of care and consolidating evidence-based practices.

 

CONFLICT OF INTEREST

The authors declare that there is no conflict of interest.

 

FUNDING

SEI-260003/006194/2024. Carlos Chagas Filho Foundation for Research Support of the State of Rio de Janeiro – FAPERJ.

 

REFERENCES

1. Campos CGP, Pacheco A, Gaspar MD da R, Arcaro G, Reche PM, Nadal JM, et al. Analysis of diagnostic criteria for ventilator-associated pneumonia: a cohort study. Rev Bras Enferm. 2021;74(6):e20190653. https://doi.org/10.1590/0034-7167-2019-0653

 

2. Campara MAS, Silva MF de O, Figueiredo PT de S. Análise sobre o conhecimento do bundle de prevenção de pneumonia associada à ventilação mecânica em um hospital de ensino do Distrito Federal. Concilium [Internet]. 2023 [cited 2024 Jan 20];23(8):80-101. Available from: http://repositorio.unb.br/handle/10482/46943

 

3. Silva WM da, Silva SJ da, Silva SB da, Souza JNVA, Júnior JA da S, Silva DP de F, et al. Atualizações sobre as medidas de prevenção de pneumonia associada à ventilação mecânica (PAVM) no adulto. Rev. Eletrônica Acervo Saúde. 2023;23(6):e12368. https://doi.org/10.25248/reas.e12368.2023

 

4. Brasil. Agência Nacional de Vigilância Sanitária. Boletim Segurança do Paciente e Qualidade em Serviços de Saúde nº 30: Avaliação Nacional dos indicadores de IRAS e RM - 2022. Brasília: ANVISA; 2022.

 

5. Howroyd F, Chacko C, MacDuff A, Gautam N, Pouchet B, Tunnicliffe B, et al. Ventilator-associated pneumonia: pathobiological heterogeneity and diagnostic challenges. Nat Commun. 2024;15(1):6447. https://doi.org/10.1038/s41467-024-50805-z

 

6. Brasil. Agência Nacional de Vigilância Sanitária. Medidas de prevenção de infecção relacionada à assistência à saúde. Brasília: Anvisa; 2017.

 

7. Institute for Healthcare Improvement. How-to Guide: Prevent Ventilator-Associated Pneumonia. Cambridge (MA): Institute for Healthcare Improvement; 2012.

 

8. Papazian L, Klompas M, Luyt CE. Ventilator-associated pneumonia in adults: a narrative review. Intensive Care Med. 2020;46(5):888-906. https://doi.org/10.1007/s00134-020-05980-0

 

9. Zhao T, Wu X, Zhang Q, Li C, Worthington HV, Hua F. Oral hygiene care for critically ill patients to prevent ventilator-associated pneumonia. Cochrane Database Syst Rev. 2020;12(12):CD008367. https://doi.org/10.1002/14651858.cd008367.pub4

 

10. Güner CK, Kutlutürkan S. Role of head-of-bed elevation in preventing ventilator-associated pneumonia bed elevation and pneumonia. Nurs Crit Care. 2022;27(5):635-645. https://doi.org/10.1111/nicc.12633

 

11. Weinberger J, Cocoros N, Klompas M. Ventilator-Associated Events: Epidemiology, Risk Factors, and Prevention. Infect Dis Clin North Am. 2021;35(4):871-899. https://doi.org/10.1016/j.idc.2021.07.005

 

12. Wicky PH, Martin-Loeches I, Timsit JF. HAP and VAP after Guidelines. Semin Respir Crit Care Med. 2022;43(2):248-254. https://doi.org/10.1055/s-0041-1740246

 

13. Gaspar MD da R, Rinaldi ECA, Mello RG, Santos FA dos, Nadal JM, Cabral LPA, et al. Impact of evidence-based bundles on ventilator-associated pneumonia prevention: A systematic review. J Infect Dev Ctries. 2023;17(2):194-201. https://doi.org/10.3855/jidc.12202

 

14. Guillamet CV, Kollef MH. Is Zero Ventilator-Associated Pneumonia Achievable? Updated Practical Approaches to Ventilator-Associated Pneumonia Prevention. Infect Dis Clin North Am. 2024;38(1):65-86. https://doi.org/10.1016/j.idc.2023.11.001

 

15. Ferreira JC, Vianna AO de A, Pinheiro BV, Maia IS, Baldisserotto SV, Isola AM, et al. Joint statement on evidence-based practices in mechanical ventilation: suggestions from two Brazilian medical societies. Crit Care Sci. 2025;37:e20250242en. https://doi.org/10.62675/2965-2774.20250242-en

 

16. Martinez-Reviejo R, Tejada S, Jansson M, Ruiz-Spinelli A, Ramirez-Estrada S, Ege D, et al. Prevention of ventilator-associated pneumonia through care bundles: A systematic review and meta-analysis. J Intensive Med. 2023;3(4):352-364. https://doi.org/10.1016/j.jointm.2023.04.004

 

17. Bucoski S de S, Oliveira TMC de, Koeppe GBO, Oliveira PP, Mattos MR de, Cerqueira L da CN. Variação da pressão do CUFF em pacientes graves submetidos à ventilação mecânica invasiva sob os cuidados de enfermagem em unidade intensiva. Nursing (Ed. brasileira. Online). 2020;23(265):4245-4256. https://doi.org/10.36489/nursing.2020v23i265p4245-4256

 

18. Pinto AC da S, Silva BM da, Santiago-Junior JF, Sales-Peres SH de C. Efficiency of different protocols for oral hygiene combined with the use of chlorhexidine in the prevention of ventilator-associated pneumonia. J Bras Pneumol. 2021;47(1):e20190286. https://doi.org/10.36416/1806-3756/e20190286

 

19. Klompas M, Branson R, Cawcutt K, Crist M, Eichenwald EC, Greene LR, et al. Strategies to prevent ventilator-associated pneumonia, ventilator-associated events, and nonventilator hospital-acquired pneumonia in acute-care hospitals: 2022 Update. Infect Control Hosp Epidemiol. 2022;43(6):687-713. https://doi.org/10.1017/ice.2022.88

 

20. Almeida KMV da, Barros OMC de, Santos GJC, Valença MP, Cavalcanti ATA, Ferreira KO. Adesão às medidas de prevenção para pneumonia associada à ventilação mecânica. Rev. enferm. UFSM. 2015;5(2):247-256. https://doi.org/10.5902/2179769215411

 

21. Alecrim RX, Taminato M, Belasco AGS, Barbosa D, Kusahara DM, Fram D. Good practices in the prevention of ventilator-associated pneumonia. Acta Paul. Enferm. (Online). 2019;32(1):11-17. https://doi.org/10.1590/1982-0194201900003

 

Submission: 13-Jan-2025

Approved: 14-Aug-2025

 

Editors:

Rosimere Ferreira Santana (ORCID: 0000-0002-4593-3715)

Geilsa Soraia Cavalcanti Valente (ORCID: 0000-0003-4488-4912)

Suzana Mangueira (ORCID: 0000-0003-0931-8675)

 

Corresponding author: Lucas Rodrigo Garcia de Mello (garcialucas@id.uff.br)

 

Publisher:

Escola de Enfermagem Aurora de Afonso Costa – UFF

Rua Dr. Celestino, 74 – Centro, CEP: 24020-091 – Niterói, RJ, Brazil

Journal email: objn.cme@id.uff.br

 

AUTHORSHIP CONTRIBUTIONS

Project design: Silva BC, Mello LRG.

Data collection: Silva BC.

Data analysis and interpretation: Silva BC, Mello LRG, Henrique DM.

Writing and/or critical review of the intellectual content: Silva BC, Mello LRG, Henrique DM, Mesquita AF, Nepomuceno RM, Almeida LF, Lisboa CD, Christovam BP.

Final approval of the version to be published: Silva BC, Mello LRG, Henrique DM, Mesquita AF, Nepomuceno RM, Almeida LF, Lisboa CD, Christovam BP.

Responsibility for the text in ensuring the accuracy and completeness of any part of the paper: Silva BC, Mello LRG, Henrique DM, Mesquita AF, Nepomuceno RM, Almeida LF, Lisboa CD, Christovam BP.

 

image3.png